MFT-TH: purification system modules with rigid pocket filters - Aerservice Equipments srl
Product guide Shop Download

FILTER MODULES

MFT-TH

Purification system modules with rigid pocket filters


APPLICATIONS
The MFT-H mechanical filter modules with rigid pocket filters were designed and manufactured to be inserted as filter systems in centralised fume gas extraction systems in industrial contexts.
Given the high efficiency of the filters installed in the different modules, these may also be expanded for use with other types of fumes; depending on the composition, they are recommended for the filtration of welding fumes (even oily), for the treatment of air in civil facilities, for the reduction of solvents in low concentrations, as well as odour removal processes.
Considering the reduced size, the filters can be installed in places with limited availability of space. Furthermore, the smaller versions can be equipped with wall-mounted applications which help to optimise the useful spaces of the work area.
The activated carbon filter module has a load bearing containment structure, formed by extruded aluminium profiles. These support the double-wall panels, pre-painted in grey RAL 7032, galvanised inward facing sides, interposed with 25 mm polyurethane foam to ensure a perfect water-tight seal of the module.
The filters, fitted to a guide, are housed inside.
The MF TH version for laboratories and environments with air-quality management, has the same technical and manufacturing features as the standard version, apart from the filter section for the insertion of a HEPA pocket filter (completely incinerable) with filter class H12, certified according to EN 1822.

MOD. MFFLOW RATEHEAD LOSSFILTER CLASSEFFICIENCY ILHFILTER SURFACES
m³/hPaClassWELDINGm²
50 T5000600F895%17
70 T7000600F895%25,5
100 T10000600F895%34
120 T12000600F895%42,5
150 T15000600F895%51
200 T20000600F895%68
50 TH5000600H1299,97%17
70 TH7000600H1299,97%25,5
100 TH10000600H1299,97%34
120 TH12000600H1299,97%42,5
150 TH15000600H1299,97%51
200 TH20000600H1299,97%68
MOD.50 T70 T100 T120 T150 T200 TFILTER THICKNESSEFFICIENCYPENETRATION
Metallic pre-filter 287x592x22NO1NO12NO22 mmG2 25%10 ≥ P μm
Metallic pre-filter 592x592x2211222422 mmG2 25%10 ≥ P μm
Pleated Pre-filter 287x592x98NO1NO12NO98 mmEU4 - G4 70%10 ≥ P > 3 μm
Pleated Pre-filter 592x592x9811222498 mmEU4 - G4 70%10 ≥ P > 3 μm
Pocket filter 287x592x292NO1NO12NO292 mmF8 95%1≥ P > 0,3 μm
Pocket filter 592x592x292112224292 mmF8 95%1≥ P > 0,3 μm
MOD. MF-EDIMENSIONSØ IN/OUT*TOTAL WEIGHT
LxHxP mmmmKg
50700x700x60025060
70700x1040x60030080
100700x1400x600350100
120700x1740x600450120
1501400x1040x600450140
2001400x1400x600500160
The IN/OUT diameters are recommended and available in the optional input and output hoppers.

DIFFERENTIAL PRESSURE GAUGE

Differential pressure meter with instant analogue display of the measured value.
N.B. This accessory serves to provide complete and immediate control on the state of the filters

WALL-MOUNTED SHELF

Wall bracket kit consisting of galvanised steel and guides for fixing to the filter module.
Wall-mounted installation is only possible for smaller modules to facilitate their installation and eliminate any risks related to heavier wall-mounted modules.
KIT for MF 50 (E - T - C)
KIT for MF 50 (EC - TC)
KIT for MF 70 (E - T - C)

PLENUM FOR ARM AIR EXTRACTION

Powder coated and welded steel adapter for connecting MF 50 filter module to IBS - IBSA - IBF series extractor arm.
N.B. This accessory serves to create a wall-mounted module which can provide mechanical or electrostatic filtration by means of modules MF 50 T and MF 50 E

ROUNDED SQUARE FITTING

Hopper in galvanised steel to be secured to the filter module by means of connection to the rigid hose in extraction and expulsion.
Two fittings are required in order for installation to be carried out correctly.

REGULATING DAMPER

Circular butterfly damper with graduated control in galvanised sheet metal to provide greater control on the air flow rate and speed, as well as for adjusting extraction fan performance ensuring it operates within its standard parameters.